Coombs test – Water Valves manufacturer – DNC Air Cylinder

Mechanism
Schematic showing the direct and indirect Coombs tests.
The two Coombs tests are based on the fact that anti-human antibodies, which are produced by immunizing non-human species with human serum, will bind to human antibodies, commonly IgG or IgM. Animal anti-human antibodies will also bind to human antibodies that may be fixed onto antigens on the surface of red blood cells (also referred to as RBCs), and in the appropriate test tube conditions this can lead to agglutination of RBCs. The phenomenon of agglutination of RBCs is important here, because the resulting clumping of RBCs can be visualised; when clumping is seen the test is positive and when clumping is not seen the test is negative.
Common clinical uses of the Coombs test include the preparation of blood for transfusion in cross-matching, screening for atypical antibodies in the blood plasma of pregnant women as part of antenatal care, and detection of antibodies for the diagnosis of immune-mediated haemolytic anemias.
Coombs tests are done on serum from venous blood samples which are taken from patients by venepuncture. The venous blood is taken to a laboratory (or blood bank), where trained scientific technical staff do the Coombs tests. The clinical significance of the result is assessed by the physician who requested the Coombs test, perhaps with assistance from a laboratory-based hematologist.
Direct Coombs test
The direct Coombs test (also known as the direct antiglobulin test or DAT) is used to detect if antibodies or complement system factors have bound to RBC surface antigens in vivo. The DAT is not currently required for pre-transfusion testing but may be included by some laboratories.
Examples of diseases that give a positive direct Coombs test
The direct Coombs test is used clinically when immune-mediated hemolytic anemia (antibody-mediated destruction of RBCs) is suspected. A positive Coombs test indicates that an immune mechanism is attacking the patient’s own RBC’s. This mechanism could be autoimmunity, alloimmunity or a drug-induced immune-mediated mechanism.
Examples of alloimmune hemolysis
Hemolytic disease of the newborn (also known as HDN or erythroblastosis fetalis)
Rh D hemolytic disease of the newborn (also known as Rh disease)
ABO hemolytic disease of the newborn (the indirect Coombs test may only be weakly positive)
Anti-Kell hemolytic disease of the newborn
Rh c hemolytic disease of the newborn
Rh E hemolytic disease of the newborn
Other blood group incompatibility (RhC, Rhe, Kidd, Duffy, MN, P and others)
Alloimmune hemolytic transfusion reactions
Examples of autoimmune hemolysis
Warm antibody autoimmune hemolytic anemia
Idiopathic
Systemic lupus erythematosus
Evans’ syndrome (antiplatelet antibodies and hemolytic antibodies)
Cold antibody autoimmune hemolytic anemia
Idiopathic cold hemagglutinin syndrome
Infectious mononucleosis
Paroxysmal cold hemoglobinuria (rare)
Drug-induced immune-mediated hemolysis
Methyldopa (IgG mediated type II hypersensitivity)
Penicillin (high dose)
Quinidine (IgM mediated activation of classical complement pathway and Membrane attack complex, MAC)
(A memory device to remember that the DAT tests the RBCs and is used to test infants for haemolytic disease of the newborn is: Rh Disease; R = RBCs, D = DAT.)
Laboratory method
The patient’s red blood cells (RBCs) are washed (removing the patient’s own serum) and then incubated with antihuman globulin (also known as Coombs reagent). If immunoglobulin or complement factors have been fixed on to the RBC surface in-vivo, the antihuman globulin will agglutinate the RBCs and the direct Coombs test will be positive. (A visual representation of a positive direct Coombs test is shown in the upper half of the schematic).
Indirect Coombs test
The indirect Coombs test (also known as the indirect antiglobulin test or IAT) is used to detect in-vitro antibody-antigen reactions. It is used to detect very low concentrations of antibodies present in a patient’s plasma/serum prior to a blood transfusion. In antenatal care, the IAT is used to screen pregnant women for antibodies that may cause hemolytic disease of the newborn. The IAT can also be used for compatibility testing, antibody identification, RBC phenotyping, and titration studies.
Examples of clinical uses of the indirect Coombs test
Blood transfusion preparation
Main articles: blood transfusion and cross-matching
The indirect Coombs test is used to screen for antibodies in the preparation of blood for blood transfusion. The donor’s and recipient’s blood must be ABO and Rh D compatible. Donor blood for transfusion is also screened for infections in separate processes.
Antibody screening
A blood sample from the recipient and a blood sample from every unit of donor blood are screened for antibodies with the indirect Coombs test. Each sample is incubated against a wide range of RBCs that together exhibit a full range of surface antigens (ie blood types).
Cross matching
The indirect Coombs test is used to test a sample of the recipient’s serum against a sample of the blood donor’s RBCs. This is sometimes called cross-matching blood.
Antenatal antibody screening
The indirect Coombs test is used to screen pregnant women for IgG antibodies that are likely to pass through the placenta into the fetal blood and cause haemolytic disease of the newborn.
Laboratory method
The IAT is a two-stage test. (A cross match is shown visually in the lower half of the schematic as an example of an indirect Coombs test).
First stage
Washed test red blood cells (RBCs) are incubated with a test serum. If the serum contains antibodies to antigens on the RBC surface, the antibodies will bind onto the surface of the RBCs.
Second stage
The RBCs are washed three or four times with isotonic saline and then incubated with antihuman globulin. If antibodies have bound to RBC surface antigens in the first stage, RBCs will agglutinate when incubated with the antihuman globulin (also known Coombs reagent) in this stage, and the indirect Coombs test will be positive.
Titrations
By diluting a serum containing antibodies the quantity of the antibody in the serum can be gauged. This is done by using doubling dilutions of the serum and finding the maximum dilution of test serum that is able to produce agglutination of relevant RBCs.
Coombs reagent
Coombs reagent (also known as Coombs antiglobulin or antihuman globulin) is used in both the direct Coombs test and the indirect Coombs test. Coombs reagent is antihuman globulin. It is made by injecting human globulin into animals, which produce polyclonal antibodies specific for human immunoglobulins and human complement system factors. More specific Coombs reagents or monoclonal antibodies can be used.
Enhancement media
Both IgM and IgG antibodies bind strongly with their antigens. IgG antibodies are most reactive at 37C. IgM antibodies are easily detected in saline at room temperature as IgM antibodies are able to bridge between RBC owing to their large size, efficiently creating what is seen as agglutination. IgG antibodies are smaller and require assistance to bridge well enough to form a visual agglutination reaction. Reagents used to enhance IgG detection are referred to as potentiators. RBCs have a net negative charge called zeta potential which causes them to have a natural repulsion for one another. Potentiators reduce the zeta potential of RBC membranes. Common potentiators include low ionic strength solution (LISS), albumin, polyethylene glycol (PEG), and proteolytic enzymes.
History of the Coombs test
The Coombs test was first described in 1945 by Cambridge immunologists Robin Coombs (after whom it is named), Arthur Mourant and Rob Race. Historically, it was done in test tubes. Today, it is commonly done using microarray and gel technology.
References
^ F. Rosen and R. Geha, Case Studies in Immunology, 4th ed., Garland Science, p.173.
^ Coombs RRA, Mourant AE, Race RR. A new test for the detection of weak and “incomplete” Rh agglutinins. Brit J Exp Path 1945;26:255-66.
External links
Coombs testing – Institute for Transfusion Medicine.
Coombs test – direct – Medlineplus.org.
Coombs test – indirect – Medlineplus.org.
Acute Anemia – emedicine.com
Drugs that cause haemolytic anemia – Merck Manual.
MeSH Coombs’+Test
v  d  e
Transfusion medicine
General concepts
Apheresis  (plasmapheresis, plateletpheresis, leukapheresis)  Blood transfusion  Coombs test (direct and indirect)  Cross-matching  Exchange transfusion  International Society of Blood Transfusion  Intraoperative blood salvage  ISBT 128  Transfusion reactions
Blood group systems  Blood types
ABO  Chido-Rodgers  Colton  Cromer  Diego  Dombrock  Duffy  Gerbich  GIL  Hh  Ii  Indian  JMH  Kell (Xk)  Kidd  Knops  LW  Lewis  Lutheran  MNS  OK  P  Raph  Rh and RHAG   Scianna  T-Tn  Xg  Yt  Other
Blood products
Blood donation  Blood substitutes  Cryoprecipitate  Platelets  Plasma  Red blood cells  Whole blood  Fresh frozen plasma
v  d  e
Operations/surgeries and other procedures of the hemic and lymphatic system (ICD-9-CM V3 40-41)
Lymphatic system
Lymphadenectomy  Neck dissection  Retroperitoneal lymph node dissection
Bone marrow and spleen
Stem cell transplantation/Hematopoietic stem cell transplantation  Splenectomy
Imaging
Lymphogram
Immunologic techniques
and tests 
serology/
diagnostic immunology
Immunoprecipitation
Chromatin immunoprecipitation  Immunodiffusion (Ouchterlony double immunodiffusion, Radial immunodiffusion, Immunoelectrophoresis, Counterimmunoelectrophoresis)
Immunoassay
ELISA  Enzyme Multiplied Immunoassay Technique  RAST test  Radioimmunoassay  Immunofluorescence
Agglutination
Hemagglutination/Hemagglutinin (Coombs test)  Latex fixation test
Other
Nephelometry  Complement fixation test  Immunocytochemistry  Immunohistochemistry (Direct fluorescent antibody)  Epitope mapping  Skin allergy test  Patch test
lymphocyte navs: cells/physio, immunodeficiency/immunoproliferative immunoglobulin/neoplasia, proc
lymphatic organ navs: anat, physio, lymphatic disease/splenic disease/thymus disorders/thymus neoplasia/vascular tumors, proc
Categories: Transfusion medicine | Hematology | Immunology | Medical tests

The e-commerce company in China offers quality products such as Water Valves manufacturer , DNC Air Cylinder, and more. For more , please visit pneumatic equipments suppliers today!

Processing your request, Please wait....

Leave a Reply